4.  Parameters (User) 
4.1  Workpiece Coordinate 
 
 
 
I-142 
 
 
Measure points B and C in the same 
way, and set them. 
6) 
(Note) Width center workpiece offset 
measurement is performed 
when only points A and B are 
set. 
Perform the measurement by 
one axis. 
Point A 
Point B
Point C 
 
 
 
Set the setting number of workpiece 
coordinate system, then press the 
INPUT key. 
#( 54 )(                )(            )(            ) 
7) 
The hole center is calculated from 
points A, B and C. 
The value that subtracted external 
workpiece offset value from the 
calculated hole center value is set. 
The setting column highlight returns to 
normal and the value is cleared to 0.
 
 
 
Return the sensor to the reference 
point, and turn OFF the 
measurement switch. 
8) 
The message "  WLM  " disappears.
 
 
 
(3)  Width center workpiece offset measurement procedure 
 
 
Perform an operation such as a 
reference point return to position the 
tool on the reference point.
1) 
 
 
 
Turn ON the measurement switch on 
the machine operation board. 
2) 
The message "  WLM  " appears. 
 
 
 
Move the sensor into the groove 
using manual feed and manual 
handle feed. 
3)