Справочник Пользователя для Mitsubishi Electronics 60/60S

Скачать
Страница из 559
4.  Parameters (User) 
4.3  I/O Parameters 
 
 
 
I-160 
4.3  I/O Parameters 
 
 
Pressing the menu key 
 
 
I/O PARA 
 displays the I/O BASE PARAM screen. 
 
There are basically two types of input/output parameters which must be set when inputting, outputting or 
referring to data, or when performing tape operation. One type is the parameters related to the input/output 
device. The baud rate, etc., is set according to each device. Up to five types of input/output devices can be 
registered. The other type of input/output parameters is the I/O base parameters which determine which 
device is connected to which channel per input/output application. 
 
 
4.3.1  I/O BASE PARAM 
 
 
  [I/O BASE PARAM] 
PARAM 
2.1/7 
 
 <I/O> 
#  <PORT No.> 
#   <DEV. No.>
<DEV.NAME>
DATA 
IN 
9001
- 9002
-  
DATA 
OUT 
9003
- 9004
-  
NC 
RUNNING 
9005
- 9006
-  
MACRO 
PRINT 
9007
- 9008
-  
PLC 
IN/OUT 
9009
- 9010
-  
REMOTE PROG IN 
9011
9012
RIN 
EXT 
UNIT 
9013
0 9014
0  
 
 
 
 
 
 
   
     
 
 # (      )  DATA(  ) 
 
WORK PROCESS 
I/O PAR 
SETUP MENU 
 
 
<I/O> 
<PORT No.> 
<DEV. No.> <DEV. NAME> 
 
 
Specify the board No. to which the serial 
input/output device is connected to 2. 
• Set “1” to use ch1. 
• Set “2” to use ch2. 
 
Set the input/output device No. 
for each application. 
The device Nos. are 0 to 4 and 
correspond to the input/output 
device parameters.  
The device name set in the 
input/output device parameter is 
also displayed for identification. 
DATA IN 
9001  Specify the port for inputting the data 
such as machine program and 
parameters. 
9002 Specify the No. of the device that 
inputs the data. 
DATA OUT 
9003  Specify the port for outputting the data 
such as machine program and 
parameters. 
9004 Specify the No. of the device that 
outputs the data. 
TAPE MODE 
9005  Specify the input port for running with the 
tape mode. 
9006 Specify the No. of the device to 
be run with the tape mode. 
MACRO 
PRINT 
9007  Specify the output port for the user 
macro DPRINT command. 
9008 Specify the No. of the device for 
the DPRINT command. 
PLC IN/OUT 
9009  Specify the port for inputting/outputting 
various data with PLC. 
9010 Specify the No. of the device for 
the PLC input/output. 
REMOTE 
PROG IN 
9011  Specify the port for inputting remote 
programs. 
9012 Specify the number of the device 
used to input remote programs. 
EXT UNIT 
9013  Specify the port for communication with 
an external unit. 
9014 Specify the number of the unit 
used for communication with an 
external unit