6.  Data In/Out 
6.5  PROGRAM FILE 
 
 
 
I-264 
 (Note 
1)  If a large number of short programs are registered or edit operation is performed frequently, the 
memory use efficiency lowers because of the memory configuration and (CHARACTER + 
REMAIN) becomes less than the maximum number of available characters that are stored. If the 
difference between them is extremely large, the condense function can be used to improve the 
memory use efficiency. 
 (Note 
2)  If preparing comment, space (
 
 
SP 
) can be written in it. But, the space is ignored after registration 
for efficient use of memory. 
 (Note 
3)  When using the 2-part system, the system name of the currently selected system is displayed as 
$1 (system 1) and $2 (system 2). This is not displayed when using a 1-part system. (Only L 
system) 
 (Note 
4)  Whether to show or hide name of the selected system can be switched with the parameters. The 
list of machining program numbers can also be switched with the parameters. 
#1050 
MemPrg 
#1285 
ext21/bit0 
#1286 
ext22/bit0
System name display 
Program number list display
0, 2, 4, 6 
The name of the selected 
system is not displayed. 
The numbers of the machining 
programs registered in the 
memory common for the 
systems are listed. 
1, 3, 5, 7 
OFF 
 - 
OFF 
The name of the selected 
system is displayed. 
The numbers of the machining 
programs registered in the 
memory for the selected system 
are listed. 
 ON 
ON 
The name of the selected 
system is not displayed. 
The numbers of the machining 
programs registered in the 
memory for all systems are 
listed.