Справочник Пользователя для Mitsubishi Electronics 60/60S
6. Data In/Out
6.7 Data Protection
I-267
2) Protection of user parameters and common variables (KEY 2)
When KEY 2 is turned OFF, the operation items listed in Table 2 are inhibited.
Table 2 Data protection by KEY 2
No. Operation
Screen
1
Machining parameter setting
PARAM/PROCESS
2
Control parameter ON/OFF
PARAM/CONTROL
3
Axis parameter setting
PARAM/AXIS
4
Barrier data
PARAM/BARRIER
5
Common variable setting
MONITOR/COMMON VARIABLE
6
I/O basic parameter setting
IN/OUT (PARAMETER)
7
Parameter tape input
IN/OUT/INPUT
8
Parameter tape output
IN/OUT/OUTPUT
(Note) When KEY 2 is OFF, pressing any key other than the MENU key on the screens corresponding
to numbers 1 to 6 in Table 2 does not enter any data, but displays message "DATA
PROTECT".
PROTECT".
When an attempt is made to perform the operation of number 7 or 8, pressing the
INPUT
key
cannot input or output any data, causing message "DATA PROTECT" to be displayed.
3) Protection of machining program (KEY 3)
When KEY 3 is turned OFF, the operation items listed in Table 3 are inhibited.
Table 3 Data protection by KEY 3
No. Operation
Screen
Extended
operation menu
1
Storing MDI data in memory
MDI
MDI ENTRY
2
Editing machining program
EDIT
—
3
Creating machining program
EDIT
PROGRAM
4
Setting comments of stored program
EDIT
FILE
5
Storing and checking machining program in
memory
memory
IN/OUT/INPUT
—
6
Erasing machining program (single, group, all)
IN/OUT/ERASE
—
7
Setting comment of stored program
IN/OUT/FILE
—
8
Copying, condensing, and merging a machining
program, and changing its number
program, and changing its number
IN/OUT/COPY
—
9
Outputting machining program
IN/OUT/OUTPUT
—
10 Modifying the buffer of machining program
MONITOR/
COORDINATE
COORDINATE
—
(Note
1) When KEY 3 is OFF, pressing any key other than the MENU key on the screens corresponding to
numbers 1 to 4 and 6 to 8 in the above table or the extended operation menu screen causes
message "DATA PROTECT" to be displayed; no data can be input.
message "DATA PROTECT" to be displayed; no data can be input.
When an attempt is made to perform the operation of number 5, 9, or 10 in Table 3, pressing the
INPUT
key (for 5 and 9) or the cursor key (for 10) causes message "DATA PROTECT" to be
displayed without the operation coming into effect.
(Note
2) When using the 2-part system, editing, input and output of the machining programs in all systems
can be prohibited with the data protection key 3 (Y23A).