Appendix 7. 
Operation Messages on Setting and Display Unit
 
 
 
IV-24 
 
Error No. 
Error message 
Details 
E03 
No. NOT FOUND 
∆  •  The corresponding setting No. (#) was not found. This error 
occurs if a setting No. not found on the screen was set and input‚ 
or if a variable No. not found in the specifications was set and 
input for the common variables. 
•  When the tool length was measured manually, a nonexisting tool 
wear compensation number was specified and the sensor was 
turned ON.  Specify the R register of the offset number correctly.
E04 
DEV. NOT READY 
×  •  The input/output unit power is not ON.  
•  The cable is disconnected. 
•  Setting of the transfer speed (baud rate) does not agree. 
E05 NOT 
ACCEPTABLE 
×  •  The PLC timer cannot be set from the screen when the program 
is valid. (When machine parameter bit selection #6449 bit 1 is set 
to 1.) 
•  The PLC counter cannot be set from the screen when the 
program is valid. (When machine parameter bit selection #6449 
bit 0 is set to 1.) 
 
 
 
•  The tool registration data setting is prohibited. (When special 
relay E71 is valid by the PLC.) 
•  Setting from the tool life management screen is prohibited. 
 
 
 
•  Absolute position setting screen’s #1 “ORIGIN” and #2 “ZERO” 
cannot be set when #0 “INIT SET” is invalid. 
 
 
 
•  The total of axes set in #1001 SYS_ON‚ #1002 axisno is illegal. 
Set so that the total No. of axes is within the specifications range 
for the target model. 
•  #1037 cmdtyp is not within the setting range. 
 
 
 
•  The INPUT key was pressed to perform search for the program 
that is in background edit status on the word edit screen. 
•  The menu keys (Replace and Insert) on the word edit screen 
were manipulated when a running program is displayed (PDISP 
signal: ON). 
•  An attempt was made to set MDI data in an MDI setting lock state 
(the MDI setting lock parameter is specified with 0 and a non-MDI 
mode is valid). 
 
 
 
•  Language data in display selection status was entered.  Change 
the display selection status once before entering the data.  
(#1043 lang) 
 
 
 
•  When the manual value command protection (#1228 aux12/bit7) 
function is valid, the first monitor screen was manipulated by 