Справочник Пользователя для Mitsubishi Electronics 60/60S
Appendix 7.
Operation Messages on Setting and Display Unit
IV-25
Error No.
Error message
Details
E06 NO
SPEC
× • The menu key for a function not in the specifications was
pressed.
• A parameter not in the specifications was set.
• A language that was not added as an option was selected.
• A language that was not added as an option was selected.
(#1043 lang)
• Set up parameter #1049 mmac_R was set to “1” when the
machine manufacturer macro option was not valid.
• Set up parameter #1060 SETUP was set to “20” when the
machine manufacturer macro option was not valid.
• Writing of the machine manufacturer macro program with the
PROGRAM COPY screen was attempted when the machine
manufacturer macro option was not valid.
manufacturer macro option was not valid.
E07 RESET
END
∆ • The input/output operations were forcibly stopped by reset‚ etc.
(including EMG).
E08 PHYSICAL
ERR
× • The input/output parameter setting or input/output unit side
setting was incorrect.
E09 TIME
OUT
× • The input/output unit parameter “#9116 TIME-OUT SET” setting
was too short.
• There is no EOB code in the machining program.
E10 MEMORY
OVER
× • The program cannot be written because the memory capacity is
exceeded.
• This error occurs when the MDI data setting on the MDI screen
exceeds 500 characters‚ or when saving MDl‚ editing or making a
program on the edit screen‚ input on the data input/output screen‚
program copy‚ etc.
program on the edit screen‚ input on the data input/output screen‚
program copy‚ etc.
E11
PROG. No. DUPLI
∆ • When registering a machining program in the memory‚ a program
with the same No. as the designated program No. was found in
the memory. Refer to the program file to find a program No. not
being used‚ and reset the program No.
the memory. Refer to the program file to find a program No. not
being used‚ and reset the program No.
• A program with the same No. as the machining program to be
copied from the memory was found in the IC card.
• This error occurs during MDI registration in the MDI screen or
during creation of a program in the edit screen.
E12 FILE
ENTRY
OVER
× • When registering a machining program in the memory‚ the No. of
programs determined in the specifications is exceeded‚
preventing registration.
This error occurs during MDI registration in the MDI screen‚
creation of a program in the edit screen‚ data input in the data
input/output screen‚ and program copy.
preventing registration.
This error occurs during MDI registration in the MDI screen‚
creation of a program in the edit screen‚ data input in the data
input/output screen‚ and program copy.
E13 NB
NOT
FOUND
∆ • The block with the designated sequence No. or block No. does
not exist in the designated program.
E14 PROG.
NOT
FOUND
∆ • The designated program is not found in the memory.
• The corresponding program No. was not found with search of
tape memory during graphic check.