5   DATA USED FOR POSITIONING CONTROL 
 
5.1.3 Setting items for zero point return parameters 
When carrying out "zero point return control", the "zero point return parameters" must 
be set. The setting items for the "zero point return parameters" are shown below. 
The "zero point return parameters" are set commonly for each axis. 
Refer to "Chapter 8 ZERO POINT RETURN CONTROL" for details on the "zero point 
return control", and to section "5.2 List of parameters" for details on each setting item. 
 
Zero point return control
Zero point return parameters 
Machine zero point return control 
High-speed zero 
point return control
Zero point return basi
parameters
 
Pr.45
  Zero point return method 
N
ear-point 
dog method
 
Stopper stop 
method 1)
 
Stopper stop 
method 2)
 
Stopper stop 
method 3)
 
C
ount 
method 1)
 
C
ount 
method 2)
 
Value set for 
machine zero point 
return control are 
used. 
Pr.46
  Zero point return direction 
 
Pr.47
  Zero point address 
 
Pr.48
  Zero point return speed 
 
Pr.49
  Creep speed 
 
Pr.50
  Zero point return retry 
– 
Zero point return detail
ed 
parameters
 
Pr.51
  Zero point return dwell time 
– 
Pr.52
 
Setting for the movement amount after 
near-point dog ON 
– – – –   
 
Pr.53
 
Zero point return acceleration time 
selection 
 
 
 
 
 
 
Pr.54
 
Zero point return deceleration time 
selection 
 
 
 
 
 
 
Pr.55
  Zero point shift amount 
Pr.56
  Zero point return torque limit value 
– 
– – 
Pr.57
 
Speed designation during zero point 
shift 
S S S S S S 
Pr.58
  Dwell time during zero point return retry
– 
 
 
 :  Always set 
  –  :  Setting not required (This is an irrelevant item, so the setting value will be ignored. If the value is the default value or 
within the setting range, there is no problem.) 
  R  :  Set when using the section "12.2.1 Zero point return retry function". ("–" when not set.) 
  S  :  Set when using the section "12.2.2 Zero point shift function". ("–" when not set.)
 
 
 
 Checking the zero point return parameters. 
 
Pr.45  to  Pr.58  are checked with the following timing. 
 
(1)  When the " remote station READY signal" changes from OFF to ON 
(2)  When the test mode using the AD75 software package