Chapter 2 - CommissioningConfiguring Parameters Required for Management Connectivity
Chapter 2: Commissioning
Configuring Parameters Required for Management Connectivity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
38
External Management Next Hop Gateway. Must be within the range defined by the External Management IP Address
and External Management Subnet Mask. The default is 0.0.0.0 (must be changed to a valid value if the IP address of
external management equipment is not within the range defined by the External Management IP Address and External
Management Subnet Mask). In Unified Connectivity Mode, should be configured to the value of the Bearer Next Hop
Gateway.
External Management VLAN ID. The default is 12. In Unified Connectivity Mode, should be configured to the value of
the Bearer VLAN ID. Otherwise, it must differ from the Bearer VLAN ID.
Local Management IP Address and Local Management Subnet Mask. You may change the Local Management IP
Address (the default is 172.31.0.1) and Local Management Subnet Mask (the default is 255.255.255.0). However, it is
recommended to always maintain the default value to ensure availability of known IP parameters for local connectivity.
2.4.3
Configuring the L1 and L2 Parameters (If Necessary)
The default Port Negotiation Mode of all ports is auto. Typically Auto-negotiation mode should be used. However, if the
physical interface parameters must be set manually for Data Port 2 or Data Port 3, do the following:
Select the applicable port (BTS > Connectivity > L1 & L2 > Select > Port Number > 2/3).
Select the Update option.
Configure the Port Negotiation Mode parameter to manual.
Configure the required Port Speed (10/100/100 for Port Number 2, 10/100 for Port Number 3).
Configure the required Duplex Mode.
Note: If Data Port 1 is up, its Port Negotiation Mode is forced to Full Duplex.
2.4.4
Configuring the SNMP Authorized Manager and Traps Manager
2.4.4.1
Configuring the Authorized Manager
By default, the unit is supplied with one SNMP Traps Manager with the following parameters:
Manager Number: 1
Community Read Only: public
Community Read and Write: private
If different communities are used by the management system, you should add an SNMP Authorized Manager with the
correct communities or update the existing one.
To add an Authorized Manager:
Select BTS > Management > Authorized Managers > Add. You are prompted to configure the Manager Number, the
Community Read Only and the Community Read and Write.
To update the default Authorized Manager:
1
Select BTS > Management > Authorized Managers > Select.