Chapter 2 - CommissioningActivating the Unit
Chapter 2: Commissioning
Activating the Unit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
39
2
At the Manager Number prompt, enter 1 and select the Update option. You are prompted to configure the Community 
Read Only and the Community Read and Write.
2.4.4.2
Configuring the SNMP Traps Manager
By default, the unit is supplied with one SNMP Traps Manager with the following parameters:
IP Address: 192.168.1.60
Port Number: 162 (This is the default port number used by the management system.)
Community: public
Enable Traps Distribution: enable
If different parameters are used by the management system, you should add an SNMP Traps Manager with the correct 
parameters. The IP Address of an existing SNMP Traps Manager cannot be updated.
To add an SNMP Traps Manager:
Select BTS > Management > SNMP Traps Managers > Add. You are prompted to configure the IP Address, the Port 
Number, the Community and the Enable Traps Distribution parameter.
2.4.5
Applying the Configuration
To apply the changes, reset the unit by selecting BTS > Unit Control > Shutdown operation > Update and then select the 
Reset option.
After the unit reboots, it should be discoverable and manageable from remote by the EMS station. 
If you do not use pre-prepared offline configuration files, the following section provides details about how to configure 
additional parameters required for activating the unit using either the management system (after discovering the unit) or the 
Monitor program.
2.5
Activating the Unit
To activate the unit you must:
1
Create the BS.
2
Define the Antenna(s).
3
Configure Radio Cluster parameters.
INFORMATION
Once the unit can be discovered by the management system, the best way to complete the 
commissioning process is by using offline configuration files pre-prepared using the Mass 
Configuration Wizard. For more details, refer to the Using the Mass Configuration Wizard section in the 
Management System Infrastructure Manual and to the Using the Offline Tool Wizard section in the 
Device Driver Manual.