Chapter 2 - CommissioningConfiguring Parameters Required for Management Connectivity
Chapter 2: Commissioning
Configuring Parameters Required for Management Connectivity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BreezeCOMPACT System Manual
BreezeCOMPACT System Manual
37
2.4
Configuring Parameters Required for Management 
Connectivity
This section describes the minimum mandatory configuration actions required to allow remote management of the site and to 
enable discovery by the Element Management System:
2.4.1
Configuring the BTS Number
In the Main menu of the Monitor program, select BTS > General > Update and configure the BTS number. The BTS 
Number must be unique in the Radio Access Network. The default (0) is not a legitimate value.
2.4.2
Configuring the Management and IP Interfaces Connectivity 
Mode Parameter
The default Connectivity Mode is inband. If a different Connectivity Mode is required, select 
BTS > Connectivity > Management and IP Interfaces. You are prompted to configure the following parameters (for 
some parameters, you can press Enter to keep the default value).
Bearer Subnet Mask. The default is 255.255.255.0.
Bearer Next Hop Gateway. Must be within the range defined by the BS Bearer IP Address and Bearer Subnet Mask. The 
default is 0.0.0.0. Must be changed to a valid value if the IP addresses of core network equipment are not within the 
range defined by the BS Bearer IP Address and Bearer Subnet Mask.
Bearer VLAN ID (default 11).
Default Authenticator IP. The default is 0.0.0.0. Must be changed to a valid value if the IP address of default 
authenticator ASN-GW is not within the range defined by the BS Bearer IP Address and Bearer Subnet Mask.
External Management IP Address. Must be unique in the managed network. The default is 192.168.1.1. Note that in 
Unified Connectivity Mode, the External Management IP Address should be within the address range defined by the BS 
Bearer IP Address and Bearer Subnet Mask.
External Management Subnet Mask. The default is 255.255.255.0. In Unified Connectivity Mode, should be configured 
to the value of the Bearer Subnet Mask.