Справочник Пользователя для Mitsubishi Electronics C64T

Скачать
Страница из 317
16.  Auxiliary Axis Parameters 
 
 
 
291 
16.  Auxiliary Axis Parameters 
Turn the NC power OFF after setting parameters indicated with a (PR) in the table. The setting will be 
validated after the power is turned ON again. 
 
No. Name 
Details 
Setting 
range
Default 
value 
(PR) 
MSR 
Motor series 
Set the motor series. This is automatically judged 
by the system when the default value (0000) is 
set. 
0000 to FFFF 
(hexadecimal) 
0000 
(PR) 
RTY Regeneration 
option type 
Set the regenerative resistor type. Do not set values without a description. 
 
0 0 0 0 (Default 
value) 
 
 
 
 
Setting 
value 
Details 
 
 
 
Amplifier standard built-in resistor (10CT 
has no built-in resistor) 
    
Setting 
prohibited 
    
MR-RB032 
(30W) 
    
MR-RB12 
(100W) 
    
MR-RB32 
(300W) 
    
MR-RB30 
(300W) 
    
MR-RB50 
(500W) 
 
 
 
 
7~F 
 
 
(PR) 
PC1 Motor 
side 
gear ratio 
(machine 
rotation ratio) 
1 to 32767 
(PR) 
PC2 Machine 
side 
gear ratio 
(motor rotation 
ratio) 
Set the No. of gear teeth on the motor side and 
the No. of gear teeth on the machine side as an 
integer reduced to its lowest terms. 
Set the total gear ratio if there are multiple gear 
levels. 
For rotation axes, set the No. of motor rotation 
speed per machine rotation. 
1 to 32767 
(PR) 
PIT 
Feed pitch 
Set 360 (default value) for rotation axes.  
Set the feed lead for linear axes. 
1 to 32767 
(
° or mm) 
360 
6 INP  In-position 
detection width 
In-position is detected when the position droop 
becomes this setting value or less.  
1 to 32767 
(1/1000
° or µm)
50