Section 1
General Information
Programming & Operation 4-3
MN715
Program Mode
Use the Program Mode to customize the control for a variety of applications by
programming the operating parameters.  In the Display Mode, press the PROG key to
access the Program Mode.  To return to the Display Mode, press the DISP key.  Note that
when a parameter is selected alternately pressing the Disp and Prog keys will change
between the Display Mode and the selected parameter.  When a parameter is selected
for programming, the keypad display gives you the following information:
Parameter Status
Parameter
Value and Units
Parameter Status
All programmable parameters are displayed with a P: in the lower left hand corner of the
keypad display.  If a parameter is displayed with a V:, the setting may be viewed but not
changed while the motor is operating.  If the parameter is displayed with an L:, the setting
is locked and the security access code must be entered before any changes can be
made.
Parameter Blocks Access for Programming
Use the following procedure to access parameter blocks to program the control.
Action
Description
Display
Comments
Apply Power
Keypad Display shows this
opening message.
Logo display for 5 seconds.
If no faults and programmed for
LOCAL operation.
Display mode.
If no faults and programmed for
REMOTE operation.
Display mode.
If fault is displayed, refer to the
Troubleshooting section of this
manual.
Press PROG key
Press ENTER to access preset
speed parameters.
Press 
 or 
 key
Scroll to the ACCEL/DECEL
block.
Press ENTER to access Accel
and Decel rate parameters.
Press 
 or 
 key
Scroll to the Level 2 Block.
Press ENTER to access Level 2
Blocks.
Press ENTER key
First level 2 block display.
Press 
 or 
 key
Scroll to Programming Exit menu.
Press ENTER to return to display
mode.
Press ENTER key
Return to display mode.