Garland MCO-GS-10E 用户手册

下载
页码 28
 
12 
Entry 
Exit 
 
UPO - User Preference Offset.  Used by the user to adjust the controlling temperature +/- 50º in 1º 
increments.
 
 
1. 
Set the time digits to 00:00. 
2. 
Set the temperature digits to X10º. 
3. 
Depress & hold the Start button for five seconds. 
4. 
“UPO” & Current UPO will be displayed.  Turn TEMP or TIME dial to adjust. 
 
1. 
Depress the 
 
Actual Temp 
 
button to lock-in. 
 
TO CHANGE FAHRENHEIT  TO CELSIUS (and vise versa)
 
 
 
1. 
Set the time digits to 00:00. 
2. 
Set the temperature digits to X20º. 
3. 
Depress & hold the Start button for five seconds. 
4. 
Rotate either dial to display FFF or CCC in the temperature display 
 
1. 
Depress the 
 
Actual Temp 
 
button to lock-in. 
 
 
TIMER RESOLUTION CHANGING
 
 
 
1. 
Set the time digits to 00:00. 
2. 
Set the cook temp to  X30º 
3. 
Depress & hold the Start button for five seconds. 
4. 
Rotate either dial to display “HR” or “MN”. 
 
1. 
Depress the 
 
Actual Temp
 
button to lock-in. 
 
 
CHANGE THE HERTZ 
 
 
1. 
Set the time digits to 00:00. 
2. 
Set the cook temp to  X40º 
3. 
Depress & hold the Start button for five seconds. 
4. 
Rotate either dial to display “50” or “60” Hz. 
 
1. 
Depress the 
 
Cancel  button to 
 
lock-in. 
 
CHAIN PROGRAMMING
 
 
 
1. 
Press Pgm Mode on/off. 
2. 
Select Pgm # (1-5). 
3. 
Enter Event 1 parameters (time, temp, fan speed etc.).  Press Event # key to 
 
chain 2
nd
 event. 
4. 
Enter Event 2 parameters. 
5. 
Continue procedure up to six events. 
 
 
1. 
Press Pgm 
 
Mode on/off to 
 
exit program 
 
mode. 
 
ELECTRONIC PILOT & MAIN BURNER IGNITION SEQUENCE 
 
FIRST STAGE - TRIAL FOR PILOT IGNITION 
 
On  every  call  for  heat  (system  start),  the  S86  performs  an  internal  safe-start  check  shows  that  a  flame-simulating 
condition is present.  During a normal start, the S86 opens the pilot valve in the gas control.  This allows gas to flow to 
the pilot burner.  Simultaneously, the electronic spark generator in the S86 produces a 15,000 volt spark pulse output.  
This voltage produces a spark at the pilot burner ignitor/sensor rod, igniting the gas flowing around the electrode.  If 
the pilot flame is not detected during the trial for pilot ignition, the S86H contains a safety lockout timer (90 Seconds) to 
limit the trial for pilot ignition period. 
 
SECOND STAGE - MAIN BURNER OPERATION 
 
When  the  pilot  flame  is  established,  a  flame  rectification  circuit  is  completed  to  the  burner  ground.    The  S86  flame 
sensing  circuit  detects  the  flame  current  and  shuts  the  spark  generator  off.    At  the  same  time,  the  second  operator 
(main gas valve) is opened in the gas control, allowing gas flow to the main burners.  The pilot flame ignites the main 
burner conventionally.  
SAFETY LOCKOUT TIME