GAS KETTLES 
— 6 — 
 
 
GAS CONNECTIONS 
 
 
Gas supply connections and  any pipe  joint compound  must be resistant to the action  of 
propane gases. 
 
Codes require that a gas shutoff valve be installed in the gas line ahead of the kettle. 
 
Connect the gas supply line to the gas valve on the kettle. Make sure the pipes are clean and free of 
obstructions, dirt and piping compound. 
 
The gas line must be capable of delivering gas to the kettle without excessive pressure drop at the rate 
specified on the nameplate. Suggested gas supply line pressure is 7" Water Column (1.75 kPa) for 
natural gas and 11" Water Column (2.75 kPa) for propane. Burner manifold pressure is (-)1.4" Water 
Column (0.350kPa) for natural gas and (-)1.4" Water Column (0.350 kPa) for propane. 
 
The proper sizing and installation of the gas connection is important for the machine to operate within 
its design specifications. In some installations, the gas supply may not be sufficient enough to allow 
all the gas equipment to operate properly at peak loads; or when other equipment with a high BTU/ 
hr. input requirement is operating. The connection to the machine becomes even more important in 
this type of location. Flexible gas connectors with quick disconnect or swivel fittings (when used) and 
gas connectors beyond the length necessary will reduce the BTU/hr. flow capacity to the machine. 
 
NOTE:  Do not use corrugated stainless steel tubing for commercial gas equipment supply connections. 
 
NOTE:  A straight  gas  connection  is  the  ideal  condition  for  the  rated  BTU/hr.  flow  capacity  of  the 
connector. If a straight connection is not possible and a flexible gas connector is used, do not twist, 
kink or excessively flex the connector beyond a U shape. Flexing the gas connector as described will 
restrict gas flow or may damage the connector. 
 
Changing a flexible gas connector may raise the BTU/hr. flow capacity enough to allow the machine 
to operate within its design specifications. (i.e. Removing the quick disconnect fitting, installing a shorter 
gas  connector  or  installing  a  larger  diameter  gas  connector.)  An  alternative  may  be  to  move  the 
equipment to a  different gas  supply  location  in  the kitchen.  (i.e. Closer  to the main  supply  into  the 
kitchen or away from other equipment with high BTU/hr. input requirements.) 
 
 
 
 
 
 
        KETTLE 
WALL
 
KETTLE 
WALL
 
 
 
 
 
 
INCORRECT INSTALLATION 
CORRECT INSTALLATION
 
 
 
 
 
 
Prior to lighting, check all joints in the gas supply line for leaks. Use soap and 
water solution. Do not use an open flame. 
 
 
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.