Connection:  
Standard Residential 1/2” ID gas service line - 1/2” NPT male with 1/2” flare adapter.
Operating Pressure:
4.0” W.C.P. Nat. 
Supply Pressure:
6” to 14” W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.
Check with your local gas utility company or with local codes for instructions on installing gas supply lines.  Be sure to check on
type and size of run and how deep to bury the lines.  If the gas line is too small, the grill will not function properly.
To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 1/2” (1.3 cm) female flare adaptor
to the 1/2” (1.3 cm) male flare adaptor on the regulator assembly.  Ensure that the regulator arrow points in the direction of the
gas flow towards the unit and away from the supply.  Attach the regulator assembly to the grill unit by pulling back the female
coupler sleeve towards the regulator.  Insert the coupler into themale coupler fitting on the grill until the sleeve snaps forward
securing the connection.  D
DO
O  N
NO
OT
T  ffo
orrg
ge
ett  tto
o  p
pllaacce
e  tth
he
e  iin
nssttaalllle
err  ssu
up
pp
plliie
ed
d  g
gaass  vvaallvve
e  iin
n  aan
n  aacccce
essssiib
blle
e  llo
occaattiio
on
n..
N
NO
OT
TE
E::    IIff  u
ussiin
ng
g  aa  V
Viikkiin
ng
g  G
GS
SH
H1
12
2  fflle
exxiib
blle
e  h
ho
osse
e,,    rre
em
mo
ovve
e  tth
he
e  3
3//8
8””  ffllaarre
e  aad
daap
ptte
err  aan
nd
d  aattttaacch
h  h
ho
osse
e  tto
o  tth
he
e    tth
he
e  1
1//2
2””  ((1
1..3
3  ccm
m))  m
maalle
e
ffllaarre
e  o
on
n  tth
he
e  rre
eg
gu
ullaatto
orr  aasssse
em
mb
bllyy..
Installer supplied
shut-off valve must
be easily accessible
1/2” female
flare
1/2” Male fitting
Installer supplied flexible gas line with 1/2”
female flare adaptor or Viking GSH12
Regulator Assembly
Female
coupler sleeve
Regulator
1/2” male
flare adaptor
G
GA
AS
S  C
CO
ON
NN
NE
EC
CT
TIIO
ON
N
Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate
agrees with that of the supply.  Never connect an unregulated gas line to the appliance.  An installer supplied gas shut-
off valve must be installed in an easily accessible location.  All installer supplied parts must conform to local codes, or
in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1.  IIn
n  C
Caan
naad
daa::    Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation
Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.  All pipe sealants must be an approved type
and resistant to the actions of LP gas.  Never use pipe sealant on flare fittings.  All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances.  In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.  
The side burners and the individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa).  The unit must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that