Side Burners orificed for use with LP/Propane gas come equipped with a high capacity hose/regulator assembly for
connection to a standard 20 lb. LP/Propane cylinder e
eq
qu
uiip
pp
pe
ed
d  w
wiitth
h  aa  T
Tyyp
pe
e  1
1,,  Q
QC
CC
C--1
1  cco
on
nn
ne
ecctto
orr.. (See LP/Propane tank
requirements on page 6).
Connection:  1/2” (1.3 cm) NPT male with a 1/2” (1.3) flare adapter
Operating Pressure:  10.0” W.C.P.
To connect to LP/Propane regulator/hose assembly:
Although the flow of gas is stopped when the quick disconnect system is disconnected as part of its safety feature,
you should always turn the LP/Propane tank main valve “OFF” after each use and during transport of the tank or
unit.  First connect the regulator to the unit by screwing the 1/2” flare coupling onto the 1/2” flare adapter.
Connect to the tank valve by screwing the Type 1, QCC-1 connector to the LP/Propane tank.  Open the tank valve
and check the connection between the regulator and the Type 1, QCC-1 fitting for leaks with a soapy water
solution.  If bubbles appear, tighten the connection.  Repeat until all leaks have been stopped.A
ALLW
WA
AY
YS
S  C
CH
HE
EC
CK
K
F
FO
OR
R  LLE
EA
AK
KS
S  A
AF
FT
TE
ER
R  E
EV
VE
ER
RY
Y  LLP
P//P
PR
RO
OP
PA
AN
NE
E  T
TA
AN
NK
K  C
CH
HA
AN
NG
GE
E
A
An
nyy  jjo
oiin
ntt  sse
eaallaan
ntt  u
usse
ed
d  m
mu
usstt  b
be
e  aan
n  aap
pp
prro
ovve
ed
d  ttyyp
pe
e  aan
nd
d  b
be
e  rre
essiissttiivve
e  tto
o  tth
he
e  aaccttiio
on
nss  o
off  LLP
P//P
Prro
op
paan
ne
e  g
gaass
1/2” flare
adapter
Type 1, QCC-1
connector
Tank
1/2” flare coupling
LLP
P//P
PR
RO
OP
PA
AN
NE
E  T
TA
AN
NK
K  R
RE
EQ
QU
UIIR
RE
EM
ME
EN
NT
TS
S
A dented or rusty LP/Propane tank may be hazardous and should be checked by your tank supplier.  Never use a
cylinder with a damaged valve.  All tanks should be equipped with an OPD (overfilling protection device).  This is a DOT
requirement for all tanks purchased after October 1, 1998 and will ensure that the tank is not overfilled.  The  LP/Propane
tank should be a standard 5-gal, 20 lb. gas cylinder tank approximately 12” in diameter and 18” high which must be
constructed and marked in accordance with the 
Specifications for LP/Propane Gas Cylinders of the U.S. Department of
Transportation (D.O.T.) or the National Standard of Canada, 
CAN/CSA-B339, Cylinders, Spheres and Tubes for
Transportation of Dangerous Goods; and Commission. The cylinder connection device must be compatible with the Type
1, QCC-1 connector on the outdoor cooking appliance.  The cylinder must be provided with a shut-off valve terminating in
an LP/Propane gas supply cylinder valve outlet specified, as applicable, for a 5LP-A connection.  The cylinder supply system
must be arranged for vapor withdrawal and provided with a listed overfilling prevention device.  If the appliance is stored
indoors the cylinder must be disconnected and removed from the appliance.  Cylinders must be stored outdoors in a well-
vented area out of the reach of children.