Cisco Cisco Unified MeetingPlace Audio Server 维护手册

下载
页码 313
5-11
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8106)
78-16411-01
Chapter 5      Repairing and Maintaining the 8106 Server
  Replacing the CPU
Figure 5-9
hwconfig Command
Step 5
Verify the line for the fan’s status is like line 9 in 
Note
The floppy drive and CD-ROM drive do not show up in the “hwconfig” command output even 
when they are installed and running.
Replacing the CPU
The section describes how to replace the CPU card (located on the front of the server) and the CPU 
transition module (located on the back of the server).
Warning
Handling the CPU card can result in static damage. Use an anti-static wrist strap, static-dissipating 
work surface, and anti-static bags when handling and storing the card.
Any time the CPU card is replaced, you need new license keys for the MeetingPlace server. If you 
do not have these, contact the Cisco TAC before proceeding.
The CPU card always goes into the slot labelled CPU in the front of the server. It also has a transition 
module in the same slot in the back of the server. Whenever the CPU card is replaced, this transition 
module must also be replaced.
meetingplace:tech$ hwconfig
Cabinet:                ELMA 4U
Bus architecture:       CompactPCI
Processor card:         SMM5370LATUDE S/N=6055691
    Processor:          Pentium III, Model 8, 700 MHz
    Memory:             512MB
    Temperature:        22C
    Voltages:           3.34V, 5.02V, 12.00V
Power Supplies:         OK
Fans:                   OK
SCSI Adapter:           NCR 810
    DISK 1:             36000MB (SEAGATE  ST336607LC       REV=0005)
    DISK 2:             36000MB (SEAGATE  ST336607LC       REV=0005)
Ethernet:               Intel 8225x PCI 10/100 (0001af0bc2cd)
Modem:                  Absent or unrecognized
MultiAccess Blades:
    Slot  1:            AC TP1610-4 S/N=274404  REV=0 AC0
Smart Blades:
    Slot  2:             NMS CG6000C S/N=103237639 REV=5894-B4 MSC0 PRC0