PowerScan™ PD9530/PBT9500/PM9500
Reading Parameters
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains 
on following a good read. The good read LED on time can be set within a 
range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 
100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that 
the good read LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in 100ms increments). Pad 
the result with leading zeroes to yield three digits. For example: 0 = 
000, 5 = 000, 20 = 020, etc.
3. Go to 
 and scan the ENTER/EXIT PROGRAMMING MODE bar code 
to enter Programming Mode.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in 
 representing the duration which was determined in the steps 
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar 
code to abort and not save the entry string. You can then start again 
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Program-
ming Mode.
This completes the procedure. See 
 for some examples of how to 
set this feature.
Table 40. Good Read LED Duration Setting Examples
STEP
ACTION
EXAMPLES
1
Desired Setting
Good Read LED 
stays on until 
next trigger pull 
(00)
20ms
150ms
2550ms (2.55 sec.)
2
Divide by 10 (and pad with 
leading zeroes)
000
002
015
255
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT GOOD READ LED DURATION SETTING
5
Scan Three Characters 
From 
‘0’, ‘0’ and ‘0’
‘0’, ‘0’ and ‘2’
‘0’, ‘1’ and ‘5’
‘2’, ‘5’ and ‘5’
6
Scan ENTER/EXIT PROGRAMMING MODE