Scanning Features
Product Reference Guide
                           295
Scanning Features
Scan Mode
This mode is associated with typical handheld reader operation. Selects the 
scan operating mode for the reader. The following selections are valid for all 
models:
Trigger Single: 
When the trigger is pulled, scanning is activated until one of 
the following occurs:
 has elapsed
- a label has been read
- the trigger is released
Trigger Hold Multiple: 
When the trigger is pulled, scanning starts and the 
product scans until the trigger is released or 
 has 
elapsed. Reading a label does not disable scanning. 
 
prevents undesired multiple reads of the same label while in this mode.
Trigger Pulse Multiple: 
When the trigger is pulled, continuous scanning is acti-
vated until 
 has elapsed or the trigger has been 
released and pulled again. 
 prevents undesired multi-
ple reads of the same label while in this mode.
Flashing: 
The reader flashes on and off regardless of the trigger status. Flash 
rate is controlled by 
 an
. When Flash is ON the 
imager reads continuously; when Flash is OFF scanning is deactivated. 
Always On: 
No trigger pull is required to read a bar code. Scanning is contin-
ually on. If the trigger is pulled, the reader acts as if it is in Trigger Single 
 prevents undesired multiple reads of the same 
label while in this mode.
Stand Mode: 
No trigger pull is required to read a bar code. Scanning is turned 
on automatically when an item is placed in the reader’s field of view. 
 prevents undesired multiple reads while in this mode.