Thermador PRG366JG Installationsanweisungen

Seite von 90
English 5
Installation Clearances
 F
IGURE 
1: C
ABINET 
C
LEARANCES
                          
 
                   
         
        
                       
 
For 48” Ranges   {48” (1219mm) 54” (1372mm), or 60” (1524mm) Wide Hood
                            {54” (1372mm) for Island
For 36” Ranges   {36” (914mm) or 42” (1067mm) Wide Hood
                            {42” (1067mm) or 48” (1219mm) for Island
   
   
               
        
        
        
        48” Range - 48” (1219mm)    
        36” Range - 36” (914mm)
          of combustible material
Min. distance between overhead cabinets
30” (762mm) min. from bottom
of Overhead Hood to cooking
surface. 36” (914mm) min. If
hood contains combustible 
    
materials
 minimum
18” (457mm)
        
36” (914mm) or 48” (1219mm)
 
13” (330mm)
Max Cabinet
Depth
     Range width
CAUTION!
See Figure 2
36” (914mm) Min.
 
material 
from Cooking
Surface
to combustible
      For Electrical & Gas Supply zones, 
see Figure 3. Zone sizes & positions differ 
                 according to model. 
*35
” (911mm) Min. range height
*36 ¾” (933mm) Max range height
 
with leveling legs fully extended.
 
with leveling legs fully retracted.
Gas 
Zone
Electrical
   Zone
Cooking 
Surface
5” (127mm)
min to
combustible
sidewall
material
(both sides)
as defined in the “National Fuel Gas Code” (ANSI Z223.1, Current 
Edition). Clearances from non-combustible materials are not part of the ANSI 
Z21.1 scope and are not certified by CSA. Clearances of less than 12” (305 
mm) must be approved by the local codes and/or by the local authority 
having jurisdiction.
*The range height is adjustable. The level of the range top must be at the 
same level or above the counter top level.
CAUTION: 
Do not install the range such that the oven door is flush 
with the cabinet face. A flush installation could result in 
damage to the cabinets due to exposure to high heat.