CHAPTER  14   MULTIPLIER  AND  DIVIDER/MULTIPLY-ACCUMULATOR 
14.4.5  Division operation 
 
• Initial setting 
<1>  Set the multiplication/division control register (MDUC) to 80H. 
<2>  Set the dividend (higher 16 bits) to multiplication/division data register A (H) (MDAH). 
<3>  Set the dividend (lower 16 bits) to multiplication/division data register A (L) (MDAL). 
<4>  Set the divisor (higher 16 bits) to multiplication/division data register B (H) (MDBH). 
<5>  Set the divisor (lower 16 bits) to multiplication/division data register B (L) (MDBL). 
<6>  Set bit 0 (DIVST) of the MDUC register to 1. 
 
(There is no preference in the order of executing steps <2> to <5>.) 
•  During operation processing 
<7>  The operation will end when one of the following processing is completed. 
•  A wait of at least 16 clocks (The operation will end when 16 clocks have been issued.) 
•  A check whether the DIVST bit has been cleared 
 (The read values of the MDBL, MDBH, MDCL, and MDCH registers during operation processing are not 
guaranteed.) 
• Operation end 
<8>  The DIVST bit is cleared and the operation ends.  At this time, an interrupt request signal (INTMD) is generated 
if the operation was performed with MACMODE = 0. 
<9>  Read the quotient (lower 16 bits) from the MDAL register. 
<10> Read the quotient (higher 16 bits) from the MDAH register. 
<11> Read the remainder (lower 16 bits) from multiplication/division data register C (L) (MDCL). 
<12> Read the remainder (higher 16 bits) from multiplication/division data register C (H) (MDCH). 
 
(There is no preference in the order of executing steps <9> to <12>.) 
• Next operation 
<13> Start with the initial settings of each step to change the operation mode.  When the same operation mode is 
used sequentially, settings <1> to <5> can be omitted. 
 
Remark  Steps <1> to <12> correspond to <1> to <12> in Figure 14-10. 
 
 