Renesas rl78 User Manual

Page of 1004
 
RL78/G1A 
CHAPTER  30   ELECTRICAL  SPECIFICATIONS  (G:  INDUSTRIAL  APPLICATIONS  T
A
  =  
−40  to  +105°C) 
R01UH0305EJ0200  Rev.2.00 
 
 
922  
Jul 04, 2013 
Minimum Instruction Execution Time during Main System Clock Operation 
 
T
CY
 vs V
DD
 (HS (high-speed main) mode) 
 
1.0
0.1
0
10
1.0
2.0
3.0
4.0
5.0
6.0
3.6
2.7
0.01
2.4
0.03125
0.0625
0.05
Cycle time T
CY
 [
μs]
Supply voltage V
DD
 [V]
When the high-speed on-chip oscillator 
clock is selected
During self programming
When high-speed system clock is selected
 
 
<R>