Communication Manager Maintenance-Object Repair Procedures
1076 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Failure Audit (#949)
This test is nondestructive.
This test queries the DS1 converter circuit pack for any existing circuit pack or facility failures 
and any unacknowledged cleared failure messages. Upon receiving the query request, DS1 
converter firmware sends failure reports to the maintenance software for every error in its failure 
database.
This test operates on both MOs DS1C-BD and DS1-FAC. Error counts of both MOs (DS1C-BD 
and DS1-FAC) that are displayed in the error log will be incremented when this test is executed. 
This test is executed via test board. The test is also executed internally by the maintenance 
software when an alarm is resolved
Table 368: Test #949 Failure Audit 
Error 
Code
Test 
Result
Description / Recommendation
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2000
ABRT
Timed out while waiting for a response from the circuit pack.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABRT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABRT
The timer could not be set before sending the downlink message 
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2316
ABRT
Fiber link is not administered. 
Use add fiber-link to administer the DS1 converter fiber link.
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
FAIL
The DS1 converter circuit pack reported failures or retransmitted a cleared 
failure message.
1. Enter display errors and follow the associated repair procedures 
for any DS1C-BD and DS1-FAC errors.
PASS
The DS1 converter circuit pack has no failures.