Communication Manager Maintenance-Object Repair Procedures
1088 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Table 369: Upgrading TN574 DS1 Converter Circuit Packs in a fiber-link to TN1654s — 
Duplicated PNC 
Steps
Comments
Enter status pnc.
Verify that the A-PNC is active. If the B-PNC is 
active, enter the reset pnc interchange command to 
cause the A-PNC to go active.
Enter busyout pnc-standby.
Fiber link cannot be removed if PNC duplication is 
operational. Must busyout the standby PNC first.
Enter change system-parameters 
duplication. Change the Enable 
Operation of PNC Duplication 
field to n.
Disable PNC duplication.
Enter list fiber-link.
Determine the fiber-link number that the four 
TN574 circuit packs to be upgraded are associated 
with.
Enter busyout fiber-link 
fiber#.
fiber# represents the fiber-link number 
associated with the TN574 DS1 converter 
complexes that are being upgraded to TN1654 
DS1 converter complexes.
Enter remove fiber-link fiber#.
Remove the four TN574 DS1 converter 
circuit packs from the system.
Replace the TN574 Y-cables with 
TN1654 Y-cables.
Replace the removed TN574 DS1 
converter circuit packs with TN1654 
DS1 converter circuit packs. Prior to 
installing the TN1654 boards, review the 
prior section, TN1654 Board 
Configuration Switch Settings.
If a TN1654 DS1 converter board is 
connected to an SNI board, upgrade the 
SNI to a TN573B or greater.
Wait for the circuit packs to reset.
Red and green LEDs will light and then go out.
Enter change circuit-packs 
cabinet#. Update the screen to show 
that TN1654 boards are now being used 
instead of TN574 boards. Also update 
the connected SNI, if applicable, to 
suffix B.
cabinet# represents the cabinet associated with 
a DS1 converter board. The change circuit-packs 
screen needs to be updated for all four DS1 
converter boards. Also, if needed, re-add 
translations for connected EI boards.
 1 of 2