Communication Manager Maintenance-Object Repair Procedures
1090 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Converting DS1-CONV Complex to Direct-
Connect Fiber (duplicated PNC)
Note:
Note:
The following procedure is generic in its scope. Check the customer’s switch 
configuration for EI/SNI structures.
!
WARNING:
WARNING:
Do not power down a Switch Node carrier to replace a circuit pack.
!
WARNING:
WARNING:
In duplicated PNC configurations, one DS1-CONV complex in the fiber-link 
serves as the active and the second DS1-CONV complex serves as the standby. 
Each DS1 Converter complex consists of two TN574 or TN1654 circuit packs.
Table 370: Convert from DS1-CONV to direct-connect fiber in a duplicated PNC 
Step Command/Step
Description
1.
status pnc
Verify that the A-side is active.
If the B-PNC is active, enter reset 
pnc-interchange
 and press Enter.
Then verify that the A-side is active 
(status pnc).
2.
busyout pnc-standby
Busyout the duplicated switch side.
3.
change system-parameters 
duplication
Disable PNC duplication by changing the 
Enable Operation of PNC Duplication 
field to n.
4.
list fiber-link
Lists administered fiber connections by number. 
Select the link number associated with the 
DS1-CONV complex that you are removing.
5.
busyout fiber link n
Busyout the fiber link of interest. The fiber link 
number (step 6) is n for this command.
6.
remove fiber link n
Remove the link administration for this link.
7.
change circuit-pack 
cabinet
Remove the DS1-CONV administration for the 
four designated circuit packs (cabinet is the 
cabinet number where these DS1-CONV 
complexes reside).
Press Enter.
 1 of 2