Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1130 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1002
ABRT
The system could not allocate time slots for the test. The system is under 
heavy traffic conditions or it has time slots out of service due to TDM-BUS 
errors.
1. If the system has no TDM-BUS errors and is not handling heavy 
traffic, repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present, or some 
Tone Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test.
1. Use display port location to determine the station extension or 
attendant number of the port.
2. Use status station or status attendant to determine the 
service state of the port. If the port is in use, wait until it is idle before 
retesting. Attendants are always in use (off-hook) if the handset is 
plugged in and the port is not busied out.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals up to 5 times.
Table 384: Test #13 Voice and Control Channel Local Loop Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3