7
FAIL
Conference test failed on primary channel. In some cases, users may not 
notice disruption in service. In extreme cases, conferencing feature may 
not work at all.
14
FAIL
The primary voice channel is not transmitting properly. User impact may 
range from noticing nothing to not being able to use this port.
15
FAIL
The control channel between the Processor and Digital circuit pack is not 
transmitting properly. User impact may range from noticing nothing to not 
being able to use the port. This could disrupt other users.
16
FAIL
The secondary voice channel is not transmitting properly. User impact 
may range from noticing nothing to not being able to use this port.
1. Run circuit pack tests to check the Tone Generator circuit pack and 
the Tone Detector circuit pack using test board location.
2. Resolve any problems that are detected on the Tone Generator circuit 
pack or Tone Detector circuit pack.
3. If the test still fails, replace the Digital Line circuit pack.
PASS
The test passed, and every channel is transmitting properly.
1. To ensure that this is not an intermittent problem, repeat this test up to 
10 times.
2. If noisy connections for voice or corrupted data for data transfer 
persist, examine the station, connections, and wiring.
Table 384: Test #13 Voice and Control Channel Local Loop Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3