E-DIG-STA (Emulated Digital Line)
Issue 1 June 2005
1133
 
1392
ABRT
This is currently a TTI port, and the test cannot execute on it.
1. Verify that the port is a TTI port using either display port (the 
display shows that the port is a TTI port) or list config (the 
display shows a t for the port).
2. If either list config or display port indicates that the port is 
not a TTI port, escalate the problem. If both commands indicate that 
the port is a TTI port, the abort is correct, and no action is necessary.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The message to light every station lamp was successfully sent to the port.
1. Observe the station lamps being lit when running the test. If every 
lamps does not light, the other Digital Line test results may indicate 
related problems that are causing the unlit lamps.
2. Investigate by using other Digital Line port tests and by examining the 
station, wiring, and connections.
Table 385: Test #16 DIG-LINE Station Lamp Updates Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2