Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1168 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
TN2182 Tone-Clock Circuit Pack (for Non IPSI Connected PNs)
A TN2182 is a combined Tone Generator/Tone Detector board. It provides eight Enhanced Tone 
receiver (ETR) ports. Each of these ports provides the functions previously found individually on 
DTMR-PTs, GPTD-PTs and CLAS-PTs ports. Each port on the TN2182 may be used for any 
tone-detection function that was previously done by TN748, TN420, or TN744 Tone Detection 
boards.
The TN2182 provides Mu-law or A-law tone-detection capability.
Since the TN2182 also provides Tone-Clock function, only one TN2182 circuit pack may reside 
in a PN (or two if your system is duplicated). If more tone-detection resources are needed, the 
additional resources must be provided by TN748, TN420, or TN744 circuit packs.
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1, 257, 513: There are two possible alarm levels for this error type: major alarm 
and minor alarm. These alarm levels are dependent on the administered thresholds for 
TTR, CPTR, and CCTR. Each ETR port is capable of operating an any of these.
A major alarm is raised if the total number of ports capable of TTR, CPTR or CCTR 
detection currently in service is less than or equal to one-half of the administered TTR, 
CPTR, or CCTR threshold number. Otherwise, a minor alarm is raised. In either case, run 
the short test sequence against the port (ETR-PT) and follow the error code procedures for 
the individual tests.
The threshold number of ports for service is administered using change 
system-parameters maintenance
.
If a major or minor alarm occurs, follow this repair procedure.
Table 402: ETR-PT Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
1 (
any
Test #43 Tone Detector Audit/Update 
Test
MAJ
MIN
ON
test port location r 2
18
busyout port
WRN
OFF
release port location
257 (
)
17666
Test #43 Tone Detector Audit/Update 
Test
MAJ
MIN
ON
test port location r 3
513 (
any
Test #43 Tone Detector Audit/Update 
Test
MAJ
MIN
ON
test port location r 3