Communication Manager Maintenance-Object Repair Procedures
1242 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
ANY
FAIL
The external device alarm has been activated by the external device.
1. Clear the major alarm on the external device and repeat the test.
2. If the test fails, disconnect the external device alarm leads from the
TN2312BP IPSI circuit pack and repeat the test.
3. If the test fails, there is a problem with the analog external device alarm
port, the TN775 Maintenance circuit pack, or TN2312BP IPSI circuit
pack that reports the alarm. There are failures that can occur on the
TN775 and TN2312BP IPSI circuit pack that are not detected by their
respective maintenance, but cause many environment tests to fail. If
many environment tests fail, replace the circuit pack and repeat the test.
pack that reports the alarm. There are failures that can occur on the
TN775 and TN2312BP IPSI circuit pack that are not detected by their
respective maintenance, but cause many environment tests to fail. If
many environment tests fail, replace the circuit pack and repeat the test.
PASS
If there is a problem with the external device, but none of the following
report an alarm, the external device might not be reporting the problem
correctly or the external device might not be properly connected to the
external device alarm leads:
report an alarm, the external device might not be reporting the problem
correctly or the external device might not be properly connected to the
external device alarm leads:
●
The administered analog line external device alarm
●
TN775D or later circuit pack
●
TN2312BP IPSI circuit pack
Table 423: Test #120 Alarm query (continued)
Error
code
code
Test
result
result
Description and Recommendation
2 of 2