Communication Manager Maintenance-Object Repair Procedures
1242 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
ANY
FAIL
The external device alarm has been activated by the external device.
1. Clear the major alarm on the external device and repeat the test.
2. If the test fails, disconnect the external device alarm leads from the 
TN2312BP IPSI circuit pack and repeat the test. 
3. If the test fails, there is a problem with the analog external device alarm 
port, the TN775 Maintenance circuit pack, or TN2312BP IPSI circuit 
pack that reports the alarm. There are failures that can occur on the 
TN775 and TN2312BP IPSI circuit pack that are not detected by their 
respective maintenance, but cause many environment tests to fail. If 
many environment tests fail, replace the circuit pack and repeat the test. 
PASS
If there is a problem with the external device, but none of the following 
report an alarm, the external device might not be reporting the problem 
correctly or the external device might not be properly connected to the 
external device alarm leads:
The administered analog line external device alarm
TN775D or later circuit pack 
TN2312BP IPSI circuit pack 