Avaya 03-300430 User Manual

Page of 2574
EXT-DEV ADMIN? N (External Device Alarm)
Issue 1 June 2005
1243
 
EXT-DEV ADMIN? N (External Device Alarm)
S8700 | 8710
 / 
S8500
Note:
Note:
Use this Maintenance Object when the External Device Alarm Admin field on 
the change system-parameters customer-options form is n.
S8700 | 8710
 / 
S8500
: The IPSI monitors the EXT-DEV alarm leads.
The system only recognizes pairs connected to the 1M and 1m (ALARM MONITOR) leads. 
Refer to the DEFINITY® Communications System Generic 1 and Generic 3i Wiring 
(
555-204-111) for more details.
Hardware Error Log Entries and Test to Clear Values
MO Name in 
Alarm Log
Alarm 
Level
Initial Command to Run
1
1. Where UU is the cabinet number in the PORT field from the Alarm or Error Log.
Full Name of MO
EXT-DEV
MAJ
test environment UU
External Device Alarm
EXT-DEV
MIN
test environment UU
External Device Alarm
Table 424:  EXT-DEV ADMIN?N Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU r 2 or 6
1 or 5
Any
External Device Alarm 
(#120)
MAJ 
MIN
2
2. One port generates a MAJOR alarm; the other port generates a MINOR alarm.
OFF
test environment UU r 2 or 6