EXT-DEV ADMIN? N (External Device Alarm)
Issue 1 June 2005
1243
EXT-DEV ADMIN? N (External Device Alarm)
S8700 | 8710
/
S8500
Note:
Note:
Use this Maintenance Object when the External Device Alarm Admin field on
the change system-parameters customer-options form is n.
the change system-parameters customer-options form is n.
S8700 | 8710
/
S8500
: The IPSI monitors the EXT-DEV alarm leads.
The system only recognizes pairs connected to the 1M and 1m (ALARM MONITOR) leads.
Refer to the DEFINITY® Communications System Generic 1 and Generic 3i Wiring
(555-204-111) for more details.
Refer to the DEFINITY® Communications System Generic 1 and Generic 3i Wiring
(555-204-111) for more details.
Hardware Error Log Entries and Test to Clear Values
MO Name in
Alarm Log
Alarm Log
Alarm
Level
Level
Initial Command to Run
1
1. Where UU is the cabinet number in the PORT field from the Alarm or Error Log.
Full Name of MO
EXT-DEV
MAJ
test environment UU
External Device Alarm
EXT-DEV
MIN
test environment UU
External Device Alarm
Table 424: EXT-DEV ADMIN?N Error Log Entries
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
0
1
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test environment UU r 2 or 6
1 or 5
Any
External Device Alarm
(#120)
MAJ
MIN
2
2. One port generates a MAJOR alarm; the other port generates a MINOR alarm.
OFF
test environment UU r 2 or 6