Avaya 03-300430 User Manual

Page of 2574
EXT-DEV ADMIN? N (External Device Alarm)
Issue 1 June 2005
1245
 
External Device Alarm Test (#120)
The External Device Alarm Test requests the state of the External Device Alarm from the 
Maintenance circuit pack and reports the results. The test has no effect on the external device 
itself.
Table 426: TEST #120 External Device Alarm Test 
Error 
Code
Test 
Result
Description/ Recommendation
1000
ABRT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to ABORT with error code 2000, check for system 
powering problems with the A carrier. Look for and resolve all 
AC-POWER alarms. Then, repeat the test.
3. If the test continues to ABORT with a 2000 error code, check for and 
resolve all SYSAM errors. Then, repeat the test.
2029 
2319 
2320 
2500
ABRT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
ANY
FAIL
The External Device Alarm has been activated by the external device.
1. Clear the major alarm on the external device, and rerun the test.
2. If the test still fails, then disconnect the External Device Alarms from 
the Maintenance circuit pack and rerun the test.
3. If the test still fails, then there is a problem with the Maintenance circuit 
pack that is reporting the alarm. This circuit pack should be replaced. 
There are failures that can occur on Maintenance circuit pack’s that will 
not
 be detected by their respective maintenance, but which will cause 
many environment tests to fail. If many environment tests are failing, 
the suspect circuit pack should be replaced and the test rerun.
PASS
If there is a problem with the external device, but the Maintenance circuit 
pack connected to the device reports no alarm, then the External Device 
may not be properly reporting the problems or the External Device may not 
be properly connected to the External Device.