Avaya 03-300430 User Manual
GPTD-PT (General-Purpose Tone Detector Port)
Issue 1 June 2005
1311
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
101–
122
FAIL
FAIL
1. Run the short test sequence: test port location sh r 1.
2. If the problem persists, the system is still operating properly but system
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore the system performance to
normal, replace the tone detector circuit pack containing the defective
GPTD port.
normal, replace the tone detector circuit pack containing the defective
GPTD port.
1022
FAIL
Tone detection for the system is administered as part of a wideband
configuration, and the tone detector is not a TN420C (the only circuit pack
with this capability). GPTD ports on other types of tone detector circuit
packs are taken out of service since they cannot provide the administered
function.
configuration, and the tone detector is not a TN420C (the only circuit pack
with this capability). GPTD ports on other types of tone detector circuit
packs are taken out of service since they cannot provide the administered
function.
1. Change the tone-detection mode administered on the
system-parameters country-options screen, or remove every circuit
pack except TN420C tone detectors from the system.
pack except TN420C tone detectors from the system.
PASS
Tone Detection Verification is successful. The GPTD port is able to detect
every call-progress tone and perform level measurements of test tones.
Table 452: Test #42 Tone Detection Verification Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2