Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1530 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
NPE Connection Audit Test (#50)
The system sends the circuit pack’s on-board microprocessor a message to update the 
network-connectivity translation for its SCOTCH-NPE chip.
Red Alarm Inquiry test (#140)
N
X
X
ND
Yellow Alarm Inquiry test (#141)
N
X
X
ND
Major Alarm Inquiry test (#142)
N
X
X
ND
Minor Alarm Inquiry test (#143)
N
X
X
ND
Slip Alarm Inquiry test (#144)
N
X
X
ND
Misframe Alarm Inquiry test (#145)
N
X
X
ND
Translation Update test (#146)
N
X
X
ND
SAKI Sanity test (#53)
Y
 
 
X
D
1. N = No; this test either passes or ABORTS with Error Code 2000 (problem with NT)
2. D = Destructive; ND = Nondestructive
Order of Investigation
Apply to 
TN802?
1
Short Test 
Sequence
Long Test 
Sequence
Reset 
Board 
Sequence
D/ND
2
 2 of 2
Table 552: Test #50 NPE Connection Audit Test 
Error
Code
Test
Result
Description / Recommendation
None 
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1019
ABRT
The test aborted because a test was already running on the port.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The circuit pack’s SCOTCH-NPE chip has been updated with its 
translation.
 1 of 2