Control Channel Looparound Test (#52)
This test queries the Media Module for its Media Module vintage to verify angel communication.
Table 590: Test #52 Control Channel Looparound Test
Error
Code
Test
Result
Description/ Recommendation
None 
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL
The Media Module failed to return the Media Module code or vintage.
1. Retry the command a maximum of 5 times.
2. If the problem continues, replace the Media Module.
PASS
Communication with this Media Module is successful.
Any
NO
BOARD
The test could not relate the internal ID to the port (no board). This 
could be due to incorrect translations, no board is inserted, an incorrect 
board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use list 
config and resolve any problems that are found.
2. If the board was found to be inserted correctly, enter busyout 
board location.
3. Enter the reset board location command.
4. Enter the release board location command.
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port. 
If this is not the case, check to ensure that there is a valid board 