Avaya 03-300430 User Manual

Page of 2574
PKT-INT (Packet Interface)
Issue 1 June 2005
1823
 
NO 
BOARD
The IPSI circuit pack’s Packet Interface module is assigned, but is not 
detected as physically present.
1. If the IPSI circuit pack is present, replace it.
2. If an IPSI circuit pack is not present, insert a TN2312AP IPSI circuit 
pack in the assigned slot, and rerun the test.
1
FAIL
The Private Link Broadcast Loop-Around test failed. The Packet Interface 
module on the IPSI circuit pack enters a fatal-fault state when this occurs, 
and the Packet Interface maintenance software should put the Packet 
Interface in a out-of-service state. By the time action is taken, the test 
should abort with ABRT code 1137, and a demand reset should be used to 
test the Packet Interface.
1. This may be the result of old firmware not supporting new software 
operation. Verify the IPSI circuit pack’s firmware vintage and download 
the new firmware if appropriate.
2. The firmware image on the IPSI circuit pack may have been corrupted. 
Download the firmware image.
3. Retry the command.
4. If the same Error Code occurs, use reset packet-interface 
location to reset the Packet Interface.
For further action, see the repair procedures in 
on page 1836 for the Packet Interface Reset test (#889).
5. If the test continues to fail, replace the IPSI circuit pack.
Table 670: Test #885 Private Loop-Around Tests  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3