Avaya 03-300430 User Manual

Page of 2574
PKT-INT (Packet Interface)
Issue 1 June 2005
1837
 
NO 
BOARD
The IPSI circuit pack’s Packet Interface module is assigned but is not 
detected as physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312AP IPSI circuit pack in the assigned slot, and 
rerun the test.
5001
ABRT
The TDM clock in the Processor port network has failed.
1. See 
on page 2252 to clear this failure.
5002
ABRT
The packet bus in the Processor port network has failed.
1. See 
Any
FAIL
The diagnostic tests failed for the IPSI’s Packet Interface module failed. If 
the system is equipped with the high-reliability or critical-reliability 
configuration on an S8700 Multi-Connect or on an S8700 IP Connect, the 
reset runs only on demand if the Packet Interface is on the standby IPSI 
circuit pack, or if Packet Interface is in an out-of-service state on the active 
IPSI.
1. This may be the result of old firmware not supporting new software 
operation. Verify the IPSI circuit pack’s firmware vintage and download 
the new firmware if appropriate.
2. The firmware image on the IPSI circuit pack may have been corrupted. 
Download the firmware image.
3. Retry the command.
4. If the same Error Code occurs, retry reset packet-interface.
5. If the reset fails, replace the IPSI circuit pack.
PASS
The IPSI’s Packet Interface diagnostic software passed. The Packet 
Interface is put back into service automatically.
Table 674: Test #889 Reset Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2