Avaya 03-300430 User Manual
PMS-LINK (Property Management System Link)
Issue 1 June 2005
1845
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to the extension
where the PMS device connects. If the PMS Link is already up, then this test passes without
making any data call.
where the PMS device connects. If the PMS Link is already up, then this test passes without
making any data call.
Table 677: Test #215 Link Retry Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
10
20
20
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30
ABRT
Internal system error.
1. Refer back to
for resolution.
1010
ABRT
The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link to release the PMS Link from busyout
state.
2. Retry test pms-link to execute the test.
2012
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The PMS Link CANNOT be established.
1. Refer back to
for restoring the PMS Link.
PASS
The PMS Link is up.