RANL-STA (Remote Analog Line (Station) Port)
Issue 1 June 2005
1919
 
Notes:
a. Error Type 0: run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its procedures.
b. Error Type 1: in-line errors, can only be resolved over time.
Aux Data 40960 indicates that too many simultaneous incoming ringing attempts were 
made on this board. Only 4 ports on a board may ring simultaneously. A 5th incoming call 
will cause an inline error from the board.
Aux Data 40975 indicates that the terminal equipment was on-hook when ring-tip was 
detected during ringing. This usually indicates a failure in the terminal equipment or the 
type of terminal has a low ringer impedance. Call the terminal equipment and verify that 
the terminal rings. If the terminal does not ring, then replace it. Otherwise, enter the test 
port location
 command, and follow the procedure for Test #48.
Aux Data 40977 indicates that terminal equipment was not connected when ringing was 
attempted. Run the short test using the test port location command, and follow 
the procedure for the results of Test #48.
c. Error Type 15: A software audit error that does not indicate hardware malfunction. Run the 
short test sequence, and investigate associated errors.
d. Error Type 257: An in-line error and can only be resolved over time. This error indicates 
that ringing voltage is absent. If only one analog circuit pack in the system has this problem, 
then replace the circuit pack. If only analog circuit packs on a particular carrier have this 
error, then the ringing generator may not be connected to this carrier. If analog circuit packs 
on many carriers have this error, then it is probably a problem with the ringing generator.
18
0
busyout 
station 
extension
WRN
ON
release station extension
257 (
40973
none
513 (
Station Present 
test (#48)
WRN
OFF
test port location sh r 2
769
Battery Feed test 
(#35)
MIN 
WRN
1
ON
test port location sh r 2
2817 (
)
Hyperactive
MIN
OFF
1. Minor alarms on this MO may be downgraded to Warning alarms based on the values used in set 
options.
Table 704: Analog Line Error Log Entries  (continued)
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
 2 of 2