Avaya 03-300430 User Manual

Page of 2574
RDIG-STA (Remote Digital Station)
Issue 1 June 2005
1939
 
1392
ABRT
This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using display port, where the 
display shows that the port is a TTI port, or list config, where the 
display shows a t for the port.
2. If list config or display port indicate that the port is not a TTI 
port, escalate the problem. If both commands indicate that the port is a 
TTI port, the abort is correct, and no action is necessary.
2000
ABRT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Station audits passed. This Digital Port circuit pack is functioning properly.
1. If complaints persist, investigate by using other port tests, and by 
examining the station, wiring, and connections.
Table 712: Test #17 Station (Digital) Audits Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2