SNI-BD (SNI Circuit Pack)
Issue 1 June 2005
2089
 
140
FAIL
The SNI is physically connected to a DS1C but is not administered to be 
connected to a DS1C.
Either add the DS1 converter complex to the fiber that this SNI is 
associated with by:
1. Use list fiber-link to determine the fiber associated with the 
SNI.
2. Use remove fiber-link to remove the fiber.
3. Use add fiber-link to add the fiber back, and administer the DS1 
converter complex.
Or:
4. Remove the DS1C connection, and connect the SNI directly to its 
administered fiber endpoint.
5. Verify that the fiber-optic and metallic cable connections are installed 
as administered by entering list fiber-link.
PASS
The administered data and the circuit packs the SNI can communicate with 
match.
0
NO
BOARD
No board was detected by the test.
1. Check that board is properly translated and inserted.
2. Run the test again. If it fails, reset the board. An SNI should be reset 
instead of reseating the circuit pack. The reset board command 
should almost never be used on an SNI. It may be necessary to use 
reset board if the SNI circuit pack gets into a mode where it cannot 
communicate with software. If an SNI with active errors and alarms is 
reset, the errors and alarms may take a while to come back, therefore 
reset board can mask real problems.
3. Run the test again. If it fails, the ID chip on board may be bad. 
Replace the board and retest.
Table 752: TEST #759 Configuration Audit  (continued)
Error
Code
Test
Result
Description / Recommendation