TDM-BUS (TDM Bus)
Issue 1 June 2005
2251
 
Digit Detection Test (#297)
This test is executed on the Non-Control Channel bus. The Tone-Clock circuit is told to put a 
tone on the Non-Control Channel bus and the Tone Detector circuit is told to listen to it. The test 
passes if the tone is successfully transmitted on the Non-Control Channel bus.
Table 804: Test #297 Digit Detection Test 
Error
Code
Test
Result
Description / Recommendation
None
1001
2100
ABRT
Could not allocate the necessary system resources to run this test.
1005
ABRT
Since this test is valid only on the non-control channel bus, it aborts 
execution when run on the control channel bus. This is a valid response. 
Use status port-network to verify which bus is the control channel 
bus.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 3 times.
None
FAIL
This failure indicates that communication on the Non-Control Channel is 
not reliable.
1. Execute the command again.
2. If the problem persists, test the active Tone-Clock circuit and Tone 
Detector circuit/circuit pack in the port network where the faulted TDM 
bus resides, to make sure they are healthy. See 
3. Execute the command again.
4. If the problems persists, see 
PASS
The non-control channel bus is operational.