Communication Manager Maintenance-Object Repair Procedures
2320 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1040
ABRT
This test is not performed for trunk ports administered as access 
endpoints.
1. Verify this port is an access endpoint by using display port.
2. If the port has been administered as an access endpoint, then this 
test should abort.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run the test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times. 
1
FAIL
The E lead test failed due to an on-board port problem.
1. Replace the circuit pack.
2
FAIL
The M lead test failed. The EPF has experienced an overcurrent 
condition, perhaps due to the external M lead.
1. To make sure the problem is on-board, disconnect the facility from the 
pack and retry the test.
2. If the test fails, replace the circuit pack. Otherwise, check the external 
wiring toward the far-end PBX.
PASS
Tie Trunk EPF test is successful. This port is functioning properly.
1. If users are reporting troubles, examine loop connections to the port.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board, if 
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the port.
Table 833: Test #74 Tie Trunk EPF Test  (continued)
Error
Code
Test
Result
Description / Recommendation