Avaya 03-300430 User Manual

Page of 2574
TR-LN-BD (Trunk Line Board)
Issue 1 June 2005
2363
 
TR-LN-BD (Trunk Line Board)
S8700 | 8710
 / 
S8500
 / 
G700
The TN797 Analog Trunk and Line circuit pack provides 8 ports, any of which may be 
administered as one of the following:
Note:
Note:
G700
: The separate, but equivalent, MG-ANA MO can reside in slots 1–4 of a 
G700 media gateway. Refer to 
information about this MO.
In the U.S., Canada, and like countries, every CO trunk port of TN797 Analog Trunk and Line 
circuit packs should be administered as GS (ground-start) trunks rather than as loop-start 
trunks, because GS signaling provides disconnect supervision, and loop start does not. If for 
some reason a port on the TN797 must be administered as loop start, it must be administered 
as 1-way only – either incoming or outgoing – not only at the switch, but also at the CO switch. 
This is necessary to avoid collisions (i.e., “glare”) and other highly undesirable conditions.
The TN797 Analog Trunk and Line circuit pack does not support Neon Lamp MWI (Message 
Waiting Indication). No maintenance of the terminal connected to the Neon Analog Line circuit 
pack is performed.
For circuit pack problems, see 
Table 846: TN797 Analog Trunk and Line circuit pack – port administration
Function
Group Type Trunk Type
LED MWI
Central Office trunk (CO)
co
fx
wats
loop start
ground start
CAMA/E911 trunk
cama
Direct Inward Dialing (DID) trunk
did
wink start
immed start
Analog Line
on-or-off premises
n/a
n/a
with/without 
MWI