Communication Manager Maintenance-Object Repair Procedures
2398 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Note:
Note:
G700
: If the One-Way Span test is run between a circuit pack and an MM710 DS1 
Interface Media Module on a G700 Media Gateway, the test will fail, because the 
MM710 does not frame-align its test pattern.
af. Error Type 3999: indicates that the circuit pack sent a large number of control channel 
messages to the switch within a short period of time. If Error Type 1538 is also present, then 
the circuit pack was taken out-of-service due to hyperactivity. If Error Type 1538 is absent, 
then the circuit pack was not taken out-of-service, but it has generated 50% of the 
messages necessary to be considered hyperactive. This might be completely normal during 
heavy traffic periods. However, if this Error Type is logged when the circuit pack is being 
lightly used, it might indicate a problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with one test 
may also clear errors generated from other tests in the sequence.
Table 853: UDS1 - Demand Test order of investigation 
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
test ds1-loop
D/ND
1
Echo Cancellation test (#1420)
X
D
NPE Connection Audit test (#50)
X
ND
Control Channel Loop test (#52)
X
ND
Loss of Signal Alarm Inquiry test (#138)
X
X
ND
Blue Alarm Inquiry test (#139)
X
X
ND
Red Alarm Inquiry test (#140)
X
X
ND
Yellow Alarm Inquiry test (#141)
X
X
ND
Major Alarm Inquiry test (#142)
X
X
ND
Minor Alarm Inquiry test (#143)
X
X
ND
Slip Alarm Inquiry test (#144)
X
X
ND
Misframe Alarm Inquiry test (#145)
X
X
ND
Translation Update test (#146)
X
X
ND
ICSU Status LEDs test (#1227)
X
X
ND
SAKI Sanity test (#53)
 
X
D
 1 of 2