Avaya 03-300430 User Manual

Page of 2574
VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 June 2005
2499
 
Congestion Query Test (#600)
This nondestructive test queries the number of used buffers to determine whether the VAL 
circuit pack is congested.
Normal call handling resumes when the VAL circuit pack has recovered from congestion.
FAIL
Circuit pack has detected a failure of the Packet Interface test (#598).
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board 
location).
3. If the test continues to fail, replace the circuit pack.
PASS
The Packet Interface test (#598) passed.
Table 885: Test #598 Packet Interface Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2
If:
Then:
Used buffers are, or are nearly, exhausted
The test fails.
The test fails
The switch alarms, and announcements can fail.
Table 886: Test #600 Congestion Query Test 
Error
Code
Test
Result
Description / Recommendation
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board 
location).
3. If the problem persists, replace the circuit pack.
 1 of 2