Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
2498 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Packet Interface Test (#598)
This nondestructive test checks the packet bus interface circuitry on the VAL circuit pack. Test 
failure indicates faulty circuit pack.
1–10
FAIL
The circuit pack detects LAPD frame errors. The Error Code indicates the 
value of the on-board error counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, execute the Packet Interface test (#598) 
(test board location long).
3. If Packet Interface test (#598) fails, see repair procedures for Test 
#598.
PASS
Circuit pack detects no errors.
Table 884: Test #597 Invalid LAPD Frame Error Counter Test  (continued)
Error
Code
Test
Result
Description / Recommendation
 2 of 2
Table 885: Test #598 Packet Interface Test 
Error
Code
Test
Result
Description / Recommendation
2000
ABRT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board 
location).
3. If the problem persists, replace the circuit pack.
2012
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
2100
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
 1 of 2