Avaya 03-300430 User Manual

Page of 2574
XXX-BD (Common Port Circuit Pack/Media Module)
Issue 1 June 2005
2547
 
System Technician-Demand Tests: Descriptions and Error Codes
Investigate tests in the order presented below. Clearing Error Codes associated with the one 
test may also clear errors generated from other tests in the sequence.
Table 908: XXX-BD System Technician Demand Tests
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
D/
ND
1
1. D = Destructive; ND = Nondestructive
NPE Audit test (#50)
G700
: Aborts with Error Code 1412 on G700/
G350
X
ND
Ringing Application test (#51)
Note: This test is applicable to TN746 and TN769 
Analog Line circuit packs. 
G700
: Aborts with Error Code 1412 on G700/
G350
X
X
ND
Control Channel Loop-Around test (#52)
X
X
ND
SAKI Sanity test (#53)
Note: The SAKI Sanity test is run in the long test 
sequence for the Tone-Clock circuit packs 
(TN768, TN780) only. The test is run on other 
circuit packs or media modules only when they 
are reset using reset board location.
X
D
Neon test (#220)
Note: This test is applicable to TN746 and TN769 
Analog Line circuit packs. 
G700
: Aborts with Error Code 1412 on G700/
G350
X
X
ND