Avaya 03-300430 User Manual
XXX-BD (Common Port Circuit Pack/Media Module)
Issue 1 June 2005
2549
Ringing Application Test (#51)
This test checks the ringing application circuitry common to every port on an Analog Line circuit
pack.
pack.
Table 910: Test #51 Ringing Application Circuit Test
Error
Code
Code
Test
Result
Result
Description / Recommendation
ABRT
Internal system error. Could not allocate the necessary system resources
to run test. The circuit pack is not installed.
1000
2100
ABRT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been
aborted.
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If
the service state indicates that the port is in use, then the port is
unavailable for certain tests. (Refer to Chapter 8, for a full description
of all possible states). Wait until the port is idle before retesting.
unavailable for certain tests. (Refer to Chapter 8, for a full description
of all possible states). Wait until the port is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
1008
ABRT
Could not allocate a ringing circuit for one of the following reasons: all the
ringing circuits are in use; the ringing generator is defective; ringing
generator is not wired correctly.
ringing circuits are in use; the ringing generator is defective; ringing
generator is not wired correctly.
1. If the test continues to abort, look for RING-GEN error in Error Log.
a. If there are RING-GEN errors, see
on page 1942 and try to resolve any problem(s). Then,
go to step 2.
b. If there are no RING-GEN errors, and the test continues to abort,
enter test board location on other TN742, TN769, or TN746
Analog circuit packs. If an ABRT with Error Code 1008 occurs for
this test on other circuit packs as well, then the ringing generator
may be defective or may not be wired properly. See
this test on other circuit packs as well, then the ringing generator
may be defective or may not be wired properly. See
documentation for details. If an ABRT with Error Code 1008 does
NOT occur on the other ports, then all four ring generators are in
use. Exit from this documentation.
NOT occur on the other ports, then all four ring generators are in
use. Exit from this documentation.
2. Retry the command.
1 of 2