1004
ABRT
The port was seized by a valid call during the test. The test has been
aborted.
aborted.
1. Use display port location to determine the station extension.
Use status station to determine the service state of the port. If the
port is active, it is unavailable for certain tests. Wait until the port is idle
before testing.
before testing.
2. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
This condition indicates that the test is not applicable when the analog port is
used in a combined modem pool. This error can be ignored.
1018
ABRT
Test disabled via administration.
1. To enable the test for the particular analog station being tested, enter
change station extension.
2. Enter y in the Test field.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
System could not respond to this request.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated by using other port tests, by examining
station wiring, or by examining the station.
Table 100: Test #6 NPE Crosstalk Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 2